Abb Air Circuit Breaker Acb Specification

  • Mechanical Life
  • Up to 20,000 operations
  • Phase
  • Three Phase
  • Rated Short Circuit Breaking Current
  • Up to 100 kA rms
  • Rated Short Circuit Making Current
  • Up to 220 kA peak
  • Breaking Capacity
  • Up to 100 kA
  • Product Type
  • Air Circuit Breaker (ACB)
  • Installation Options
  • Fixed or Withdrawable
  • Function
  • Protection and Switching of Electrical Circuits
  • Poles Number
  • 3 Pole or 4 Pole (optional)
  • Rated Voltage
  • Up to 690V AC
  • Rated Current
  • Up to 6300A
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • Type L, M, H/adjustable trip curves
  • Temperature Protection
  • Integrated Overload and Short-Circuit Protection
  • Weight
  • Appx. 35 kg (varies by model)
  • Color
  • Black/Grey
  • Rated Impulse Withstand Voltage
  • 12kV
  • Service Environment
  • -5°C to +40°C, relative humidity up to 95% non-condensing
  • Operation Method
  • Manual & Electrical
  • Trip Unit
  • Electronic and Microprocessor based
  • Auxiliary Contacts
  • Available
  • Rated Insulation Voltage
  • 1000V
  • Protection Features
  • Long-time, Short-time, Instantaneous, and Ground fault protection
  • Electrical Life
  • Up to 10,000 operations
  • Accessories
  • Shunt trip, Under-voltage trip, Motor operator
 
 

About Abb Air Circuit Breaker Acb


Poles Number 3 Pole
Power Supply Voltage 415V
Rated Current 800A-6000A
Operating Frequency 50 HZ
Frequency 50-60Hz
Phase 3Phase
Voltage 415V
Rated Short Circuit Breaking Capacity 50KA
Automation Grade Automatic


Advanced Protection Features

The ABB Air Circuit Breaker is engineered with comprehensive protection features, including long-time, short-time, instantaneous, and ground fault protection. Its trip unit leverages electronic and microprocessor technology, ensuring precise fault detection and circuit isolation, safeguarding equipment and personnel from electrical hazards.


Flexible Installation and Versatility

Designed to adapt to diverse electrical distribution requirements, this ACB supports both fixed and withdrawable installations. It is available in 3 and 4-pole configurations, with adjustable trip curves (Type L, M, H) for tailored application. Its rated voltage up to 690V AC and breaking capacity up to 100 kA make it suitable for high-demand environments.


Enhanced Operation and Control

With both manual and electrical operation methods, the ABB ACB offers flexibility for different system needs. Compatible accessories like shunt trip, under-voltage trip, and motor operator allow integration into automated and remote-controlled systems, boosting operational efficiency and safety.

FAQs of Abb Air Circuit Breaker Acb:


Q: How does the ABB Air Circuit Breaker provide protection in electrical circuits?

A: The ABB ACB offers advanced protection through its electronic microprocessor-based trip unit, delivering long-time, short-time, instantaneous, and ground fault protection. This ensures rapid and accurate disconnection during overloads or faults, minimizing damage and enhancing safety.

Q: What installation options are available for the ABB ACB, and where can it be used?

A: This air circuit breaker supports both fixed and withdrawable installation modes, making it adaptable for various commercial and industrial applications. It is suitable for environments with temperatures between -5C and +40C and relative humidity up to 95% non-condensing, making it ideal for deployment across India.

Q: When is it beneficial to use auxiliary contacts and accessories like shunt trip or motor operator?

A: Auxiliary contacts and accessories such as shunt trip, under-voltage trip, and motor operator enhance monitoring, remote tripping, and automatic operation. These are beneficial for complex electrical systems requiring integration with control panels or automated safety protocols.

Q: What is the process for selecting the right ABB Air Circuit Breaker configuration?

A: To select the appropriate ABB ACB, determine your systems rated current (up to 6300A), installation type (fixed or withdrawable), number of poles, required breaking capacity, and specific protection features. Consulting with an authorized service provider or trader in India can help match product features to your project requirements.

Q: How should the ABB ACB be used for optimal performance and safety?

A: Ensure proper installation by a certified electrician and configure the adjustable trip settings according to your system demands. Routine inspection of auxiliary devices and regular testing of the trip unit can maintain reliability and performance. Adherence to manufacturers commissioning guidelines is essential.

Q: What are the main benefits of using the ABB Air Circuit Breaker in electrical systems?

A: Key benefits include robust protection against electrical faults, high breaking capacity (up to 100 kA), long electrical and mechanical life, versatile installation options, and support for modern automation through its electronic trip unit and accessory compatibility, leading to increased operational reliability and reduced downtime.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Air Circuit Breakers Category

Schneider ACB Supply Service

Schneider ACB Supply Service

Phase : Three Phase

Color : Grey

Curves : Customized

Rated Voltage : 415 Volt (V)

Mechanical Life : 15,000 Operations

Rated Frequency : 5060 Hertz (Hz)

L&T ACB Service and repair

L&T ACB Service and repair

Phase : Three Phase

Color : Black & Grey

Curves : Standard & Customized available

Rated Voltage : Up to 690V AC

Mechanical Life : Up to 10,000 Operations

Rated Frequency : 50/60 Hz

Air Circuit Breaker

Air Circuit Breaker

Phase : Placeholder Phase Information from image, other

Color : Black

Curves : Placeholder Curves Information from image

Rated Voltage : Placeholder Rated Voltage from image

Mechanical Life : Placeholder Mechanical Life from image

Rated Frequency : Placeholder Rated Frequency from image

Siemens ACB Service

Siemens ACB Service

Phase : Three Phase

Color : Siemens Standard Grey/Black

Curves : Standard and Customized Trip Curves

Rated Voltage : 690V AC

Mechanical Life : Up to 20,000 operations

Rated Frequency : 50/60 Hz